Aluminum branch wiring is not a defect you have to tear out. It is a connection problem, and in most houses it is fixable at the terminations for a fraction of what a rewire costs.
One works with the wiring you already have. The other replaces it. Which one you need depends on the condition of the conductors, not on a rule of thumb.
Every outlet, switch and splice is opened, and the aluminum conductor is pigtailed to a short copper tail using a connector listed for aluminum-to-copper and an anti-oxidant compound. The device then lands on copper.
This is the common answer, because the aluminum running through the walls is rarely the problem. The terminations are.
New copper branch circuits pulled throughout, with the old conductors abandoned in place. It is invasive, it involves drywall, and it costs several times what remediation costs.
It is the right call when the conductors themselves are damaged, when the house is being opened up anyway, or when an insurer will accept nothing else.
We will tell you which one your house needs after looking at it, including when the answer is the cheaper one.
Three of them come with somebody else's deadline attached. The fourth is the one that matters most.
It came up during a sale and now there is a closing date attached. We document the scope and what remediation involves.
Some carriers will not write a policy on aluminum branch wiring. Some will once it has been remediated and documented.
Heat at an outlet or a switch is the symptom that should not wait. It usually means a termination is already failing.
Aluminum branch circuits were common in homes built from the mid sixties to the early seventies. If yours is, it is worth knowing either way.
Aluminum branch circuits are not the same thing as the aluminum service conductors feeding most houses in Albuquerque. Those are normal and they stay. We establish which you have before quoting anything.
Device by device, looking at the condition of the conductor and the connection behind it. That is what determines whether remediation is enough.
Itemized, with remediation and rewiring laid out side by side in numbers rather than adjectives, so the choice is yours to make.
Every connection made with listed connectors, tested under load, and recorded so you have something to hand an inspector or an insurer.
Remediation is priced by the number of terminations. Rewiring is priced by the house. The gap between the two is large, which is why nothing gets quoted before it gets scoped.
Every figure is a starting point · Written itemized estimate within 24 hours
The conductor running through the wall is usually fine. The failures happen at the terminations, where aluminum expands, contracts and oxidizes differently from copper, and a connection that works loose generates heat. That is why remediation targets the connections rather than the wire.
Usually not. Pigtailing every termination to copper with listed connectors addresses the point where the failures occur, and it costs a fraction of a rewire. Rewiring is the answer when the conductors themselves are damaged, or when the house is being opened up anyway.
Houses built from the mid sixties to the early seventies are the ones to check. The conductor is marked at the panel and at the devices, though the marking is often painted over. It is worth being certain, because aluminum service conductors are normal and are not the same thing.
Many do, and most ask for documentation of what was done and with which connectors. We give you that record. Policies differ, so it is worth confirming what your carrier will accept before the work rather than after it.
No. A standard connector is not listed for an aluminum-to-copper connection, and a joint made with one is the exact failure we get called out to fix. The connector has to be listed for the purpose and used with anti-oxidant compound.
Rewiring does. Remediation depends on the scope and on which jurisdiction inspects your address. We tell you which applies to your job before we start, and we pull the permit where one is required.

We work inside banks, secured facilities and on-base jobs, and those accounts do not let an unvetted crew through the door. Every one of our electricians clears a background check before they work for us, and again every year after that.
For a panel replacement that means the person switching off your power has been checked by somebody other than us. Almost no residential electrician in this market can say that.
We cover the metro, and the name should not make a homeowner in Los Lunas wonder whether we drive out.
Arc faults start at loose connections, which is exactly what an aluminum termination becomes as it ages.