Two devices protecting against two different things. One protects people, the other protects the house. Most homes have gaps in both and do not know it.
GFCI and AFCI get named together and land in the same panel, which leaves most people assuming they do the same job. They do not, and knowing which you have matters.
A ground fault is current finding a path to ground that is not the neutral — through a wet floor, a sink, a person. A GFCI compares what goes out against what comes back and opens the circuit in milliseconds when the two do not match.
That is why code puts them in kitchens, baths, garages, crawl spaces and everywhere outdoors. Water is not required for a ground fault. It is what makes one likely.
An arc fault is current jumping a gap at a loose terminal or a damaged conductor. It does not draw enough current to trip a standard breaker, and it makes heat inside a wall where nobody sees it.
That is a fire risk rather than a shock risk, which is why AFCI protection sits at the panel and covers bedrooms and living areas rather than wet rooms.
Most houses have one and not the other, or have devices wired so that they never protected what everyone assumed they protected.
Each one points at something different, and the difference changes what we test first.
It is doing its job. Something on that circuit is leaking current to ground, and the work is finding what, rather than replacing the device and hoping.
A fault still present on the circuit, a failed device, or line and load reversed at the terminals so the reset never engages.
Sometimes a loose connection it found before anything got hot. Sometimes a motor or a dimmer it reads as an arc. Those need separating.
Inspectors and insurers flag missing protection. We document what is there, what is not, and what closing the gap involves.
Pressing the button on a GFCI tells you that device trips. It tells you nothing about what is downstream of it. We test every outlet on the circuit.
Rooms that require protection and do not have it, devices wired backwards so the outlets after them were never covered, and breakers that pass a button test and fail a real fault.
Written and itemized before anything is replaced. If part of it can wait, we tell you which part and why.
Each device confirmed under load before we leave, and a written record of what was tested. That record is the thing an inspector or an insurer asks for.
Most of it is device by device, which makes it easier to quote than a repair. These are the pieces that come up.
Every figure is a starting point · Written itemized estimate within 24 hours
A GFCI protects people. It watches for current leaving the circuit through an unintended path, such as a wet surface or a person, and opens in milliseconds. An AFCI protects the building. It listens for the electrical signature of arcing at a loose or damaged connection, which can start a fire without ever drawing enough current to trip a standard breaker.
Because it is finding a fault. Moisture in an exterior box, a failing appliance, or a damaged conductor on the circuit will all do it. The device is working. The work is finding what is leaking, which means testing the circuit rather than replacing the outlet and hoping.
Usually not on its own account. Code applies at the time work is permitted, so a house is generally allowed to stay as it was built. It becomes a requirement when you remodel, add circuits or replace the panel, and it becomes a practical question whenever an inspector or an insurer looks at the house.
Press it monthly, because that is what it is for. But it only confirms that the device itself trips. It does not tell you whether the outlets downstream are actually protected, and that is where most of the problems are. A device with line and load reversed will pass its own button test while protecting nothing past it.
Sometimes it read a motor, a dimmer or an LED driver as an arc. Sometimes it found a genuine loose connection before anything got hot. Those two need separating, because one is a nuisance and the other is the reason the breaker is there.
That is the point of doing it properly. We pull the permit where the work requires one, wire to the code in force for your jurisdiction, and stay through the inspection. Either way you get written documentation of what was tested.

We work inside banks, secured facilities and on-base jobs, and those accounts do not let an unvetted crew through the door. Every one of our electricians clears a background check before they work for us, and again every year after that.
For a panel replacement that means the person switching off your power has been checked by somebody other than us. Almost no residential electrician in this market can say that.
We cover the metro, and the name should not make a homeowner in Los Lunas wonder whether we drive out.
The full range of repair and safety work, from a dead circuit to a written safety inspection.
When the problem is a fault on the circuit rather than missing protection.
AFCI protection lives at the panel. An older panel can limit what breakers are available to you.
Written, itemized estimate within twenty-four hours from Brad or Brian. Calls answered after hours. Payment due on completion; no financing offered.