Installing a new hot tub? We install the dedicated circuit, GFCI protection, disconnect and connections your tub requires — permitted and inspected.
A spa circuit is not an outlet. It is a wet-location, high-draw circuit that people sit in, and the rules around it exist for a reason.
Ground-fault protection on the circuit feeding the tub. This one exists because the load is water and there are people sitting in it.
A means of cutting power that is visible from the tub and no more than fifty feet away. Somebody standing at the spa has to be able to kill it.
Metal parts, the pump, rebar in the pad and nearby metal all bonded together so everything sits at the same electrical potential.
Pulled before the work and signed off after. Without it, nobody has independently confirmed the three items above were done.
A spa pulls 40 to 60 amps. On a house already running air conditioning and an electric range, that is often more than the service has left.
Not the quote. We work out what the house actually draws before telling you what the job costs, because the answer changes the job.
If the panel carries it, the job is a circuit and you are done.
You need capacity before you need a circuit, and you should know that before the tub is sitting on the pad rather than after.
That is a panel job, and it is a different conversation. See service upgrades →
We would rather tell you on the phone than on delivery day.
Make, model and the spec sheet if you have it. That tells us the amperage, whether it wants 240V at 50 or 60 amps, and what the manufacturer requires for the disconnect. Dealers usually hand this over with the tub.
Whether your existing service carries the additional draw. This is the step that decides whether you are buying a circuit or a circuit plus a panel upgrade.
Itemized, from Brad or Brian, covering the run, the disconnect, the GFCI protection, bonding, the permit and the inspection. No line item appears later that was not on it.
Filed before work starts, then a dedicated 240V circuit from the panel to the spa location, disconnect mounted within sight, GFCI protection in place and bonding tied in. Usually one day.
The inspector confirms it and we are there when they do. You keep the permit number — and if you sell the house, that is what stops the spa circuit becoming a negotiating point.
The biggest variable is distance. A tub fifteen feet from the panel and a tub across the yard are the same job with very different amounts of trenching and wire in between.
EVERY FIGURE IS A STARTING POINT · WRITTEN ITEMIZED ESTIMATE WITHIN 24 HOURS
Yes. A hot tub requires its own dedicated circuit running from the electrical panel to the tub, not a shared circuit or an existing outdoor outlet. A spa is a continuous, high-draw load, and sharing the circuit causes nuisance tripping at best.
Most 240V hot tubs need a 50 or 60 amp breaker, but the size comes from the manufacturer's specification rather than a general rule. Smaller tubs sometimes need less and large ones more, which is why we ask for the make and model first.
Yes. Ground-fault protection is required on the circuit feeding a hot tub, and it is one of the specific things the inspector checks. Along with the disconnect within sight and the bonding, it is what separates a permitted spa circuit from a length of wire run to a tub.
Yes, and that is the entire point of it. The inspection is what confirms the GFCI protection, the disconnect and the bonding were actually installed. Without it, nobody has verified the three things that make a wet-location circuit safe.
Often, but not always. A spa draws 40 to 60 amps, and on a house already running air conditioning and an electric range that is frequently more than is left. We run a load calculation before quoting so you find out before the tub is delivered rather than after.
It is a switch that cuts power to the tub, mounted where somebody standing at the spa can see it — within sight and no more than fifty feet away. If something goes wrong while people are in the water, nobody should have to go looking for a breaker panel inside the house.

We work inside banks, secured facilities and on-base jobs, and those accounts do not let an unvetted crew through the door. Every one of our electricians clears a background check before they work for us, and again every year after that.
For a panel replacement that means the person switching off your power has been checked by somebody other than us. Almost no residential electrician in this market can say that.
We cover the metro, and the name should not make a homeowner in Los Lunas wonder whether we drive out.
Written, itemized estimate within twenty-four hours from Brad or Brian. Calls answered after hours. Payment due on completion; no financing offered.