Line illustration of an open electrical panel with one breaker highlighted in amber and sitting askew in its slot.

What Is a Federal Pacific Panel, and Should You Replace It?

A Federal Pacific panel is an electrical panel made by Federal Pacific Electric (FPE), most often fitted with its Stab-Lok circuit breakers. FPE built them from roughly 1950 to 1980, and they were installed in homes across the country. The problem is the breakers: testing has shown that many Stab-Lok breakers can fail to trip when a circuit is overloaded, which is the one job a breaker exists to do. If your home has one, plan to replace it.

We're Corrales Electric, a licensed electrical contractor (New Mexico License #52188), family-run in Albuquerque since 1992. Federal Pacific panels turn up regularly in Albuquerque homes built from the 1950s through the 1970s. Here is how to tell if you have one, what is actually wrong with it, and what replacing it involves.

How do I know if I have a Federal Pacific panel?

Open the panel door. Don't remove the cover. Look for any of these on the door, the inner cover or the label inside:

The label is usually on the inside of the door or along the inner cover. If it's painted over or missing, an electrician can identify it from the breakers themselves.

Two names cause confusion. “Federal Pacific Equipment Inc.” is a different company. So is the Federal Pacific company that still operates today. The panels in question are the Stab-Lok equipment made by Federal Pacific Electric.

What's actually wrong with Federal Pacific breakers?

A breaker has one job: cut power when too much current flows, before the wire overheats. Testing of Stab-Lok breakers found that a significant share didn't trip when they should have.

That failure is silent. The panel doesn't buzz or spark to warn you. It looks the way it has for fifty years, and the house runs normally, until a circuit overloads and the breaker doesn't do anything about it. The wire keeps heating instead.

That's the difference between a Federal Pacific panel and most worn-out panels. A worn panel usually tells you something is wrong. It gives you signs. This one may not.

If they're dangerous, why weren't they recalled?

That's the question we hear most, and the history explains it.

The CPSC never declared the panels safe. It stopped investigating. A missing recall is not a clean bill of health.

Can I just replace the Federal Pacific breakers?

We don't recommend it. Replacement Stab-Lok-style breakers are still sold, but they plug into the same panel design, and mixing breakers from different manufacturers in a panel creates a combination that hasn't been tested as an assembly.

Replacing breakers one at a time also leaves the rest of the equipment, the bus bar and the connections, which are typically fifty years old. The fix that solves the problem is replacing the panel.

Does a Federal Pacific panel affect insurance or selling my home?

Often, yes.

If either of those is what sent you looking, tell us the renewal or closing date when you call. We schedule the permit, the PNM disconnect and the inspection around it.

What does replacing a Federal Pacific panel involve?

It's a standard panel replacement, with a permit:

  1. Evaluation and load calculation. We confirm what the house needs now. Many homes with Federal Pacific panels are also on an older, smaller service, so this is often the moment to upgrade it.
  2. Permit. We pull the electrical permit with the right jurisdiction.
  3. Utility coordination. We schedule the disconnect and reconnect with PNM.
  4. The swap. The Federal Pacific panel comes out. A new panel goes in, with every circuit landed on a correctly sized breaker and labeled.
  5. Inspection. An electrical inspector signs off, and you keep the paperwork for your insurer or buyer.

What else do homeowners ask about Federal Pacific panels?

My Federal Pacific panel has worked fine for decades. Is it really a problem?

Working fine is exactly what a breaker that won't trip looks like. It only fails when it's asked to cut power, and you won't know it failed until something overheats.

Is it an emergency?

Not by itself. If you smell burning, see scorch marks, hear buzzing or feel heat at the panel, turn off the breaker and call today. Otherwise, it's a replace-it-this-year project, not a tonight project.

Are Zinsco panels the same problem?

Zinsco is a different manufacturer with its own history of breaker failures, and we treat it the same way: plan to replace it.

Should I flip the breakers to test them?

No. Switching a breaker on and off doesn't test whether it will trip on an overload, and old breakers can stick or fail when operated.

How do I get a Federal Pacific panel replaced in Albuquerque?

Call 505-585-4894 and you'll get Brad or Brian. We'll give you a written, itemized estimate within twenty-four hours. We pull the permit, coordinate the PNM disconnect and handle the inspection.

We work in Albuquerque, Rio Rancho, Corrales, Bernalillo, Placitas and Los Lunas.

CORRALES ELECTRIC INC.  ·  NEW MEXICO ELECTRICAL CONTRACTOR LICENSE #52188  ·  LICENSED, BONDED AND INSURED  ·  FAMILY-RUN SINCE 1992

Tell us what it's doing. We'll tell you what's needed.

Written, itemized estimate within twenty-four hours from Brad or Brian. Calls answered after hours. Payment due on completion; no financing offered.

(505) 585-4894Book a Free Estimate